Heating and ventilation pull in opposite directions in a small flat. Heating wants the doors and windows shut; ventilation wants them open. Get the balance wrong and you pay for warmth that leaks out, or sit in a stuffy room that grows mould on the north wall. In an apartment there is also a third party in the equation, the body corporate, because ducts, external walls and outdoor units are often not yours to alter. This guide takes the two topics together.
Moisture is the main job. Consumer NZ's figures show how much a household adds to the air: roughly 1.5 litres a day per person from showers and baths, 3 litres a day from cooking, 0.5 litres a day from washing clothes, 1 litre from washing dishes, 0.2 litres an hour per person from breathing and about 5 litres for each load of washing dried indoors. The aim of ventilation is to move that moisture out of the unit before it condenses on cold surfaces.
Consumer NZ's practical advice is simple: use the extractor fan when cooking or showering and leave it on for about ten minutes afterwards, open windows for ten to fifteen minutes each morning, and keep furniture and mattresses away from walls and off the floor so air can circulate. Wardrobe doors left slightly open help in cold corners.
Openable windows and doors. The healthy homes ventilation standard, as published by Tenancy Services, requires living rooms, dining rooms, kitchens and bedrooms to have openable windows. Each habitable room needs at least one window, door or skylight that opens to the outside and can be fixed in the open position, with a combined openable area of at least 5 percent of the floor area. Apartments with windows on only one side get little through-draught, so open two windows or a window and a door at the same time when you want a quick change of air.
Extractor fans. Kitchens (rooms with a cooktop) and bathrooms (rooms with a bath or shower) need a fan that vents outside. For fans installed after 1 July 2019 the minimum is a 150 mm diameter including ducting, or 50 litres per second, in a kitchen, and 120 mm or 25 litres per second in a bathroom. Older fans count if they vent outside and work, and need replacing with a compliant model when they fail. The standard says fans that do not vent outdoors do not meet it, so check where yours actually discharges.
Continuous mechanical systems. Some newer buildings have a central or unit-level system that extracts continuously. Tenancy Services says built-in systems can substitute for fans if they extract continuously to the outdoors, draw air directly from the kitchen and bathroom and are part of a building consent first received on or after 1 November 2019. For renovated homes, a continuous system serving multiple rooms must extract to the outdoors and provide at least 12 litres per second in the kitchen and 10 in the bathroom. Recirculating systems, such as HRV and DVS units, do not meet the extractor fan requirement, although Consumer NZ says that if you have a mechanical home ventilation system such as an HRV or DVS you should make sure it is switched on and well maintained.
Consumer NZ explains why heating and moisture are linked: warmer air holds more moisture, so condensation forms less readily,. Curtains and blinds help keep heat in, and sealing draughts around windows, doors and cat flaps stops warmth escaping. Opening the curtains on sunny days and closing them just before dark makes use of free heat.
Two warnings from the same guidance are worth repeating. Portable unflued gas heaters should not be used indoors because they make the air damp and fill it with dangerous gases. And a dehumidifier, or the dry mode on a heat pump, can pull excess moisture out of the air.
Under the healthy homes heating standard, a rental needs at least one fixed heater that can directly heat the main living room. Each heater must be at least 1.5 kW and, together, they must meet the capacity the room needs, which can be worked out with the official heating tool, the formula in the regulations or a professional. Heat pumps and electric heaters need a thermostat. Open fires and unflued combustion heaters do not qualify, and electric heaters other than heat pumps are limited to cases where the required capacity is 2.4 kW or less, with an allowance for topping up older installations. In a small apartment, a smaller acceptable heater may be enough.
Central heating counts if it heats the main living room directly and meets the required capacity.
Heat pumps are the usual answer for an apartment, and they come with an outdoor unit. That is where shared ownership bites. The unit titles guidance says an owner can improve their unit as long as it does not affect common areas or other units and follows body corporate rules, and where work affects common property you must get written consent. External heat pump units, refrigerant lines through a shared wall or fans on an external wall usually land in that second category.
The unit titles healthy homes example is useful here. In it, the body corporate's rules prohibited external heating units on shared property without consent, so the landlord had to take all reasonable steps to obtain consent for a heat pump. If consent was refused, the landlord would need to comply as far as reasonably practicable with another qualifying heater that does not need an external unit, and failing that, a thermostatically controlled electric heater is acceptable. Tenancy Services adds a specific allowance for landlords who do not own the whole building: if the required capacity is over 2.4 kW, at least one qualifying heater of 2 kW or more is needed, and a fixed electric heater with a thermostat is acceptable.
Penetrations for fans raise the same issue. Before commissioning a new bathroom or kitchen fan that vents through an exterior wall or into a shared riser, check the rules and ask the committee. It is far cheaper to get consent first than to remove an installation afterwards.
If you have done all of that and condensation still runs down the glass, or fans seem to move almost no air, report it. A fan that is not venting to the outside, a blocked shared duct or a failed seal can be a body corporate matter, and Tenancy Services suggests that a qualified building surveyor may need to look for hidden dampness. Tenants should tell the landlord in writing, and owners should write to the committee or manager with photos and dates.